A Review on the Cooling Techniques Implemented in Data Center Cooling

Author

Veerarapu Karteek, Vijaybabu


Abstract

 Data center cooling is the process of removing heat generated by the servers. Its primary purpose is to maintain a cool temperature so that the equipment functions efficiently without overheating. Servers consume electricity and generate a large amount of heat during operation; without proper cooling, excessive heat can affect the performance, hardware, and lifespan of the equipment. Computational fluid dynamics (CFD) is a computer-based simulation method used to study heat transfer inside a data center. CFD can predict how different cooling techniques perform under various conditions, analyze airflow distribution, improve energy efficiency, and reduce design time and cost. Recent data center cooling techniques include direct-to-chip liquid cooling, in which cold plates are attached directly to the chips and coolant circulates through the plates; immersion cooling, in which servers are immersed in a non-conducting dielectric liquid that absorbs heat directly from the components; rear door heat exchangers, in which a water-cooled unit mounted on the server rack removes heat before it enters the data center room; and AI-based smart cooling, in which artificial intelligence continuously measures temperature and airflow and automatically adjusts the cooling while maintaining safe temperatures. In this review, an exhaustive discussion of the various recent cooling techniques available in the literature is presented in detail.


Keywords

Data Center Cooling, Computational Fluid Dynamics (CFD), Heat Transfer, Airflow Distribution, Direct-to-Chip Liquid Cooling, Immersion Cooling, Rear Door Heat Exchanger (RDHx), AI-Based Smart Cooling, Energy Efficiency, Thermal Management.



Full Text:

Download Paper PDF


References


[1] Wang, Wei Lun, Yichen Li, and Kuei-Peng Lee. "Effects of airflow distribution changes on the thermal environment of IT equipment in data centers." Case Studies in Thermal Engineering 73 (2025): 106604.

[2] Nada, Sameh A., Mahmoud A. Said, and Mohamed A. Rady. "Numerical investigation and parametric study for thermal and energy management enhancements in data centers' buildings." Applied Thermal Engineering 98 (2016): 110-128.

[3] Yang, Tien-Fu, et al. "Numerical study of fluid flow and temperature distributions in a data center." Case Studies in Thermal Engineering 28 (2021): 101405.

[4] Abbas, A. M., A. S. Huzayyin, T. A. Mouneer, and S. A. Nada. "Thermal management and performance enhancement of data centers architectures using aligned/staggered in row cooling arrangements." Case Studies in Thermal Engineering 24 (2021): 100884.

[5] Jao, Yi-Chen, Ze-Wen Zhang, and Chi-Chuan Wang. "Effect of uneven heat load on the airflow uniformity and thermal performance in a small-scale data center." Applied Thermal Engineering 242 (2024): 122525.

[6] Singh, Nitesh, et al. "Innovative retrofits for enhanced thermal performance in data centers using independent row-based cooling systems." Thermal Science and Engineering Progress 57 (2025): 103101.

[7] Nada, S. A., M. A. Said, and M. A. Rady. "CFD investigations of data centers’ thermal performance for different configurations of CRACs units and aisles separation." Alexandria Engineering Journal 55.2 (2016): 959-971.

[8] Lin, Ching-Chieh, and Yang-Cheng Shih. "The optimal thermal management study of a next-generation data center." Case Studies in Thermal Engineering 26 (2021): 101031.

[9] Zhou, Huahua, Junze Zeng, Mengjie Song, Xiaoqin Sun, and Siwei Qin. "Adaptability assessment of air-cooling systems for data center with varied rack power densities." Energy and Buildings (2026): 117201.

[10] Cho, Jinkyun. "Numerical analysis of rack-based data center cooling with rear door heat exchanger (RDHx): Interrelationship between thermal performance and energy efficiency." Case Studies in Thermal Engineering 63 (2024): 105247.