Noise Reduction and Anomaly Detection in Power Quality Monitoring Using Wavelet Transforms
Author
Mr. Nitin Sharma
Abstract
Modern power distribution networks are undergoing a radical shift due to the widespread integration of renewable energy sources, power electronic interfaces, non-linear industrial loads, and high-frequency switching converters. These dynamics significantly corrupt power quality (PQ) signals with additive Gaussian noise, dynamic harmonics, transient spikes, voltage sags/swells, and flicker. Standard Fourier-based spectral analysis fails under non-stationary conditions, masking transient anomalies under high noise floors. This paper proposes a rigorous, comprehensive framework for joint noise reduction and anomaly detection in Power Quality Monitoring (PQM) utilizing Discrete Wavelet Transforms (DWT) and Stationary Wavelet Transforms (SWT). An adaptive VisuShrink/BayesShrink soft-thresholding scheme is established for de-noising high-frequency detail sub-bands without smearing steep transient boundaries. Subsequently, a dynamic Parseval Energy Norm and Wavelet Packet Singular Value Decomposition (WPSVD) feature extraction algorithm is implemented for automated anomaly localization and multi-class PQ event classification. Extensive experimental evaluations on synthetic and field-recorded IEEE 1159 benchmark datasets demonstrate an average Signal-to-Noise Ratio (SNR) improvement of 18.4 dB, a Peak Signal-to-Noise Ratio (PSNR) of 42.1 dB, and an anomaly classification accuracy exceeding 98.7% under extreme low initial SNR conditions (SNR = 5 dB).
Keywords
Power Quality Monitoring (PQM), Wavelet Transform (WT), Noise Reduction, Anomaly Detection, Discrete Wavelet Transform (DWT), Stationary Wavelet Transform (SWT), Parseval Energy, Smart Grid Analytics.
Full Text:
Download Paper PDF
References
[1] S. Santoso, E. J. Powers, W. M. Grady, and P. Hofmann, 'Power quality assessment using wavelet transform analysis,' IEEE Trans. Power Deliv., vol. 11, no. 2, pp. 924–930, Apr. 1996.
[2] IEEE Recommended Practice for Monitoring Electric Power Quality, IEEE Standard 1159-2019, IEEE Power and Energy Society, 2019.
[3] D. L. Donoho, 'De-noising by soft-thresholding,' IEEE Trans. Inf. Theory, vol. 41, no. 3, pp. 613–627, May 1995.
[4] M. Karimi, H. Mokhtari, and M. R. Iravani, 'Wavelet based on-line disturbance detection for power quality applications,' IEEE Trans. Power Deliv., vol. 15, no. 4, pp. 1212–1220, Oct. 2000.
[5] IEC 61000-4-30:2015, 'Electromagnetic compatibility (EMC) - Part 4-30: Testing and measurement techniques - Power quality measurement methods,' International Electrotechnical Commission, 2015.
[6] A. M. Gaouda, M. M. A. Salama, M. R. Sultan, and A. Y. Chikhani, 'Power quality detection and classification using wavelets,' IEEE Trans. Power Deliv., vol. 14, no. 4, pp. 1469–1476, Oct. 1999.
[7] P. K. Dash, B. K. Panigrahi, and G. Panda, 'Power quality analysis using adaptive wavelet packet transform,' IEE Proc. Gener. Transm. Distrib., vol. 150, no. 6, pp. 727–732, Nov. 2003.
[8] H. B. El-Serag and Y. G. Hegazy, 'Automated power quality disturbance classification using stationary wavelet transform and neural networks,' Electric Power Systems Research, vol. 78, no. 3, pp. 440–448, Mar. 2008.
[9] M. Misiti, Y. Misiti, G. Oppenheim, and J. M. Poggi, Wavelet Toolbox User's Guide, The MathWorks Inc., Natick, MA, 2021.
[10] R. C. Dugan, M. F. McGranaghan, S. Santoso, and H. W. Beaty, Electrical Power Systems Quality, 3rd ed. New York: McGraw-Hill, 2012.
Share your valuable work from Social Media Buttons